Detection of persons/objects that "stand out" in terms of temperature
Display of temperature differences from 0.1°C (3.4°F )
Exceeding or falling below defined temperature limits triggers event (alarm, network message, activation of a switching output)
Screening via special TR windows or the complete sensor image
Temperature range from -40 to 550°C (-40 to 1022°F)
Attention: Objects have different degrees of emission. Furthermore, radiation is reflected back from other objects. To increase the measuring accuracy, a black body radiator is therefore necessary, at best installed directly next to the object to be measured. This is the only way to ensure an exact reference value comparison. Distance and influencing environmental conditions must also be taken into account.