Release Notes for MOBOTIX HUB Software
Document Information
Publisher: |
MOBOTIX AG |
Author: |
Bernd Wilhelm, Jörg Steuerwald |
Date: |
2022-05-12 |
Document: |
MxHUB2022R1_release-notes_en_v1.html |
Confidentiality: |
public |
Contents
The MOBOTIX HUB is an open video management platform (VMP) for businesses of all types and sizes. It enables the integration of security and analysis cameras, access control systems, security systems, environmental sensors, software and hardware interfaces
to industrial plants and many more, in a common control and user interface – centrally, clearly and user-friendly. MOBOTIX IoT cameras, like many IP cameras from other manufacturers, can be integrated into the system via device-specific drivers or
via the ONVIF standard.
The flexible, scalable system is available in five different variants: from the free L1 version for small installations with up to eight cameras to the L5 variant, which enables highly distributed enterprise solutions for several thousand devices to
be implemented.
The following document provides information about the system requirements, installation, and specific features of each version of MOBOTXI HUB.
Software Releases—Overview
System Requirements
MOBOTIX HUB is suitable for installation and operation on Windows systems. The computers used must meet certain system requirements for the following software and hardware components:
- Windows operating system (Pro, Enterprise, or Server Edition)
- Microsoft SQL-Server
- .NET Framework
- CPU
- RAM
- Network card
- Disk space
- Graphics cards and graphics accelerators
Depending on the variant used (L1 to L5) of the MOBOTIX HUB, there are differences in these requirements. A detailed description of the system requirements for the different variants is available on the MOBOTIX website below Support > Download Center
> Marketing & Documentation > User Manuals > Video Management Systems > MOBOTIX HUB in the document MOBOTIX
HUB System Requirements.
Additions to the system requirements
- If you install the MOBOTIX HUB with the Single Computer option, NO Microsoft SQL Server has to be installeed already on the system. If desired, this will be installed by the HUB installer.
- The specified "Microsoft® .NET 4.7.2 Framework" is already installed on a current Windows 10 system. This can be verified by using the
Version entry of the Windows Registry Key Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft
NET Framework\Setup\NDP\v4\Client.
- The "Microsoft® .NET Core 2.1.21" listed in the system requirements is also installed by the HUB installer.
Supported
camera models
The
following MOBOTIX camera models can be integrated into MOBOTIX HUB via
device-specific drivers:
- MOBOTIX 7 cameras with
firmware versions 7.x
- MOBOTIX Mx6 cameras
x16/x26 with firmware versions 5.x
- MOBOTIX P3 cameras
x14/x24/x15/x25, T24M/T25M with firmware versions 4.x
- MOBOTIX P2 Cameras
x12/x22
- MOBOTIX MOVE Camera
Models
For the models of the MOBOTIX 7, Mx6 and P3 series, special functions are supported in the Desk Client of the MOBOTIX HUB (see below). Cameras of the two IoT model series MOBOTIX 7 and Mx6 as well as the MOVE series can alternatively be integrated via
the ONVIF standard. A list of all supported camera models can be viewed on the MOBOTIX website also in the download area of this software.
Important notes on installing on Windows systems
Meaning
of each installation file
File
|
Purpose
|
Installation
required or optional
|
MOBOTIX_HUB_VMS_Products_<Hub
version>_System_Installer.exe
|
Installation
of all server and client components
|
Required
|
MOBOTIX_HUB_Desk_Client_<Hub
version>_Installer_x64.exe
|
Installing
the Desk Client application on 64-bit Windows computers on a
distributed system
|
Optional
|
MOBOTIX_HUB_Desk_Client_<Hub
version>_Installer.exe
|
Installing
the Desk Client application on 32-bit computers on a distributed
system
|
Optional
|
MOBOTIX_HUB_Plug-Ins_<Plugin
version>_Installer.exe
|
Install
specific extensions of the Desk Client on 64-bit Windows systems
for specific app features of the MOBOTIX 7 IoT cameras
|
Optional
|
MOBOTIX_HUB_MobileServer_<Hub
version>_Installer_x64.exe
|
Installing
a server component to use a HUB Web Client or HUB Mobile Client
|
Optional
|
MOBOTIX_HUB_VideoOS_OpenNetworkBridge_<Hub
version>_Installer.exe
|
Installation
of a special server component for remote access to MOBOTIX HUB
live streams or recordings by RTSP clients via the ONVIF
interface
|
Optional
|
MOBOTIX_HUB_VMSDriverInstaller<Driver
version>.exe (available in the Support
> Download Center > Software Downloads > MOBOTIX HUB
section of the MOBOTIX website)
|
Installation
of all device-specific drivers for the different camera models
(MOBOTIX IoT, MOVE and other manufacturers)
|
Required
|
The most important installation steps
The current
values for <Hub version>, <Plugin version>and <Driver
version> are specified below specifically for the MOBOTIX HUB that is
to be installed
The
most important installation steps
The
following is an overview of the basic procedure and the most important
installation steps:
- Download
the required installation files from the MOBOTX website
- Review
and ensure the system requirements
- Run
the installation file
'MOBOTIX_HUB_VMS_Products_<Hub version>_System_Installer.exe'
with installation of the 'Management Server' on the designated computer
- The
license file (*.lic) provided by MOBOTIX
after ordering the desired MOBOTIX HUB variant is required!
- When
installing as a "Single computer", all necessary server and client components are already installed here.
- When
you install a distributed system using the "Custom" option, install the other server components on the designated computers. In this case, the first installer running generates
special files for this purpose during the installation process for each server component.
- If
needed, install "Desk Clients" on other Windows computers using the file 'MOBOTIX_HUB_Desk_Client_<Hub version>_Installer_x64.exe' or "MOBOTIX_HUB_Desk_Client_
<Hub
version>_Installer.exe".
- Install
the device-specific drivers on the Management Server computer using the file 'MOBOTIX_HUB_VMSDriverInstaller<Driver version>.exe'.
- If
needed, install a "Mobile Server" using the file 'MOBOTIX_HUB_MobileServer_<Hub
version>_Installer_x64.exe' on any suitable Windows computer.
- If
required, install an "Open Network Bridge"using the
'MOBOTIX_HUB_VideoOS_OpenNetworkBridge_<Hub
version>_Installer.exe' file on the same Windows computer on which the MOBOTIX HUB Management Server was installed.
- When installing a
HUB L1 variant and also when subsequently managing (adding/deleting) devices in such an installation, the server must be online and have unrestricted Internet access — or at least unrestricted access for outbound http/https requests
to the MOBOTIX licensing servers.
When any changes that involve licensing have been saved, the HUB server will automatically contact the licensing servers to obtain the necessary device licenses. No site-specific or security related information will be transmitted during this time.
For all other operations, the HUB server can be offline.
- When
installing a HUB variant L2 to L5 start the MOBOTIX
HUB Management Client and perform an “activation” of the license by
executing the following steps in the Basics > License
Information section of the tree structure:
- do an Online
activation by entering the access data (name and password) for the MOBOTIX Partner Portal, or
- do an Offline
activation by creating a file for the license request (*.lrq), transmission of this file to the contact person at MOBOTIX Sales and import of the file (*.scl), subsequently received from MOBOTIX Sales for activation.
This completes the configuration and allows the system to be set up and configured. A detailed description of the above steps can be found on the MOBOTIX website under Support > Download Center > Marketing
and Documentation > User Manuals > Video Management Systems >
MOBOTIX HUB > Management Client. It is strongly recommended to pay close attention to the documentation Before
you start installation and Install
a new MOBOTIX HUB system contained therein before starting the installation of a new MOBOTIX HUB system!
top
Version 2022 R1 of MOBOTIX HUB
Published on: 2022-05-12
To install the MOBOTIX HUB, please refer to the Sections System
Requirements and Important
notes on installing on Windows systems Important Notes for Installation on Windows Systems. The following applies to the names of the installation files described there:
- <Hub-Version> = '2022_R1'
- <Driver-Version> = '121a'
- <PlugIn-Version> = '2022-03-09'
Note: For more information about the features described below, see the program's online help.
New and improved features
Support for external identity providers and single sign-on.
You can now log in to the MOBOTIX HUB VMS using any external identity provider (IDP) that supports OAuth 2.0 and OIDC. Logging in using an external IDP is an alternative to logging in as an Active Directory user or a basic user. By using an external IDP, you can manage users without additional configuration in the HUB Management Client. You must use roles to configure detailed access permissions.
The external IDP can be set up to require multi-factor authentication. Logging in through an external IDP is currently supported by HUB Desk Client and HUB Management Client.
Users who log in through an external IDP are automatically added as basic users. Currently, you cannot use this feature with MOBOTIX HUB Federated Architecture.
General improvements:
Secure communication: Event and LPR servers.
To keep MOBOTIX HUB a secure product, features have been added to ensure that sensitive information is not disclosed. This feature protects personal sensitive information from disclosure and protects access to sensitive information.
The following changes have been made to MOBOTIX HUB.
- New Basic User authentication model on Event Server, LPR (Plugin and Server) and Log Server.
- New certificate group for Event Server and LPR
- HTTPS support for Event Server (bound to the new certificate group)
- HTTPS support for LPR plugin (bound to Event Server)
When upgrading existing installations, the LPR plugins (Desk Client and Management Client) MUST be upgraded to the latest version before enabling encryption on the Event Server and LPR server.
Changes compared to MOBOTIX HUB VMS 2021 R2.
The audit logs for changes to role permissions are more detailed. The logs now show both the old and new values when settings are changed.
The following changes have been made to the MOBOTIX HUB installers:
- The management server address must be a URL rather than a machine name. This gives users the ability to change the communication protocol (http vs. https) and non-default ports during installation in a very simple and intuitive way.
- When installing individual components, the correct communication protocol (https vs. http) must be specified. Single components must be specified. For example, if a recording server is installed separately from the management server. management server is installed and the management server accepts only secure communication, then an https address must be specified when installing the recording server installation. Using insecure http communication during installation is not allowed in this case. This prevents security misconfigurations of the VMS.
- It is mandatory to select a certificate during the installation of a separate, standalone component if the management server is set up to accept only secure communication. For example, if a recording server is installed separately from the management server, and the management server accepts only secure communications, encryption cannot be disabled during the installation of the recording server, and a certificate must be provided to encrypt the communications.
- During the upgrade of a standalone component, it is no longer possible to change the address of the management server. Change management server address to connect the component to another VMS. If you uninstall the component Uninstall and reinstall the component, you can specify a different management server address and thus connect the component to a different VMS connect the component to a different VMS.
- All MOBOTIX HUB VMS standalone components installed on the same computer must connect to the same management server. For example, it is no longer possible to have a recording server running on Management Server "A" on the same computer as an event server running on Management Server "B".
Changes compared to MOBOTIX HUB Management Client 2021 R2
No changes
Changes compared to Recording Server 2021 R2
The export function now has its own tab in MOBOTIX HUB Desk Client. Previously, the function was available in the export window. This provides the user with a larger workspace. In addition, frequently used functions have been made more accessible, while less frequently used functions have been grouped in a separate window. Also, the operator gets better feedback when adding video clips to the export list. All of this translates into an improved workflow with focus on what's when exporting. When MOBOTIX HUB Desk Client is running as part of a remote desktop session, the operator is notified. This information is important because hardware decoding of video in remote desktop sessions is not possible. Desktop sessions is not possible and - possibly - the CPU load is higher, which in some cases may result in a worse user experience.
The MOBOTIX HUB 2022 R1 release will be the last to support 32-bit operating systems for the Desk Client, and Windows 8.1 will be removed from the list of supported operating systems. In some cases, the audio was unnecessarily delayed compared to the video. The issue has been fixed so that audio and video are better aligned.
Changes compared to MOBOTIX HUB Mobile Clients 2021 R2.
Bookmark search has been extended to search for user-defined time intervals, keywords or specific cameras. Users can also edit the start, trigger and end time of bookmarks. The videos of the bookmarks can be displayed in the full screen. Users can delete bookmarks from the list by swiping. There is a new option to turn on the Video Diagnostics overlay on the Settings tab of the applications. Users can now see what codec, frame rate, or resolution their camera is streaming at They can also check if it is a transcoded stream or a direct stream.
Changes compared to MOBOTIX HUB Web Client 2021 R2
The bookmark search is now extended to search for predefined or user-defined time intervals, keywords or specific cameras.
New in MOBOTIX HUB Add-on products 2022 R1
Changes compared to MOBOTIX HUB LPR 2021 R2
Support for US government license plates added.
Changes compared to MOBOTIX HUB Open Network Bridge 2021 R2
There is support for UTF-8, as well as basic multicast and JPEG streaming.
top
Version 2021 R2 of MOBOTIX HUB
Published on: 2021-12-14
To install the MOBOTIX HUB, please refer to the Sections System
Requirements and Important
notes on installing on Windows systems Important Notes for Installation on Windows Systems. The following applies to the names of the installation files described there:
- <Hub Version> = '2021_R2'
- <Driver Version> = '118a'
- <PlugIn Version> = '2021-05-21'
Note: For more information about the features described below, see the program's online help.
New and improved features
Bookmark functions in Web Client and mobile Clients
Bookmark functionality has been added to the web client and to the mobile clients. Users can now add and edit bookmarks from the Web Client in a way similar to the Smart Client. Quick bookmarks can be added in Live and grid. Detailed bookmarks can
be added in Single camera Playback. The bookmark headline, description and start, event and end times can be edited. Users can also search for bookmarks via the Bookmarks tab. It is possible to filter by "My Bookmarks" and then see
the details and play the selected bookmark.
Improvements in the Management Client
- Audit logs
Audit logs created by the Identity Provider in the VMS are now accessible in the Management Client under the Audit logs tab
- Improved GDPR support
The VMS will now display a warning message when certain retention times are set to values longer than the product’s default values. This helps the VMS administrator to be aware of potential GDPR issues for data that could contain personal information.
The retention times in question are alarms, video, audio, metadata as well as audit logs.
The settings for Smart Maps are all set to unavailable for new installations, and a warning of potential GDPR issues shown when the administrator changes these.
Improvements in the Recording Server
- Behavioral after uncontrolled shutdown
Changes have been made in the Recording Server and the media database to reduce startup time after an uncontrolled shutdown of the service. Previously a directory scan was needed to rebuild information about tables in the media database.
This has been changed by introducing a small SQL database containing information about all the tables. Table information can be restored from this database in most cases after an uncontrolled shutdown. The small SQL database is implemented using SQLite
and no additional components are needed on the Re-cording Server. The SQLite database files are stored in %PROGRAMDATA%\MOBOTIX
HUB and it is recommended that this folder is excluded from anti-virus scanning.
Changes in the Desk Client
The following improvements have been implemented in this application:
- New symbols
Left panel and other places now use different icons to make it possible to differentiate fixed cameras from PTZ cameras.
- Camera and view lists
Camera list and views list in left panel now allows horizontal scroll using SHIFT + mouse scroll wheel, to make it quicker to read long camera or view names.
- Export
- Default exports options are now set in Smart Client profiles to use XProtect format option by default, as this is the recommendation to use.
- For AVI exports, if enabling this, the default is now set to mkv as this results in smaller file sizes.
- For new installations these settings are locked per default in Smart Client settings. In order for the Smart Client operator to change these, the Administrator must create a new profile or change the default Smart Client Profile
- Views
The Camera Navigator view item and Smart Client Simple Mode have been removed.
Further changes in the Mobile Clients
Please check the release notes for the mobile clients in the Apple AppStore and Google Play Store.
New functions in MOBOTIX HUB add-on products
XProtect LPR
MOBOTIX HUB LPR 2021 R1 introduces these new country modules
- Armenia (AM)
- Iraq (IRQ)
- Kyrgyzstan (KS)
In the current LPR implementation, the performance of an individual LPR server is affected by the number of active country modules installed on the individual LPR server. For the region of Europe, MOBOTIX' unofficial recommendation is to not activate
more than five country modules per LPR Server to maintain system performance. In other regions, such as the Middle East region, this recommendation does not apply.
In use cases where recognition of vehicles from a wide set of countries is required, for example boarder control, it is recommended to use the generic modules, such as the EU Generic Module. These modules are specialized in recognizing
the most common types of license plates across the various EU countries.
To cover countries that are not covered by the EU Generic Module, we have now created an Eastern Europe Generic Module which covers an additional nine countries:
- Albania
- Kosovo
- Montenegro
- Belarus
- Macedonia
- Russia
- Bosnia-Herzegovina
- Moldova
- Serbia
Resolved issues
Active Directory
Synchronization
Since the MOBOTIX HUB release 2020 R3 it has been identified that synchronization between AD and the VMS did not correctly resolve nesting of user groups across different domains. In 2021 R2 those issues have been fixed and resolving user groups now
works across all the domains under transitive trust relationship. For all non-transitive trusts the process will only resolve members of the trusted domain.
Known Limitations
The
following limitations currently apply to version 2021 R2.
- Insert
MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
- 4K
and 4MP resolutions are not supported.
- It
is better to change exposure and image settings directly on the
camera.
- "Express Search"
This search does not reliably find all cameras (for MOBOTIX drivers
and ONVIF) while searching for address ranges works reliably.
top
Version 2021 R1 of MOBOTIX HUB
Published on: 2021-08-18
To install the MOBOTIX HUB, please refer to the Sections System
Requirements and Important
notes on installing on Windows systems Important Notes for Installation on Windows Systems. The following applies to the names of the installation files described there:
- <Hub Version> = '2021_R1'
- <Driver Version> = '116a'
- <PlugIn Version> = '2021-05-21'
New and improved features
Note: For more information about the features described below, see the program's online help.
Licensing per activated channel
MOBOTIX HUB VMS products 2021 R1 introduce an improvement in the licensing model allowing more enabled channels per device than previously. Some devices now require one device license per enabled channel. The license requirements for a device can be
found in the document "List of supported devices" on the MOBOTIX web page in the section Support >
Download Center > Marketing & Documentation > Video Management
Systems > MOBOTIX HUB.
When installing 2021 R1, a warning will be shown if the amount of device licenses used by the system will be affected by the improvement in licensing. In this case, the warning provides a link to a report including those devices which will require
more than 1 device license. The warning also provides an option to cancel the installation.
Increased number of supported device channels
The number of supported device channels has increased from 16 channels to 512 channels for the ONVIF driver, from 64 channels to 512 channels for the Universal Drivers, and from 1 channel to unlimited number of channels for the MIP Driver Framework.
ONVIF driver update
The current ONVIF (one-channel) driver has been modified to support up to 512 channels per device. This means that all ONVIF conformant devices can be added to the system with the existing ONVIF driver effective of MOBOTIX HUB version 2021 R1 and later,
regardless of the number of channels. For MOBOTIX HUB versions released before 2021 R1, the ONVIF driver will still support 1-channel devices only.
The current ONVIF16 (16-channels) driver has not been changed. It will remain in the upcoming Driver Device Packs for backward compatibility but will no longer be updated with new functionality.
Universal driver update
A new Universal512 driver is now available, supporting devices with up to 512 channels.
Change in administration and functionality of basic
user accounts
User management for the concept of basic users has been changed. When a HUB system administrator creates a new basic user, a temporary password is set. It is recommended that the administrator checks the box "Force
basic user to change password on next login". The following applies to the registration process and the parameters:
- The user will be redirected to a change password page when he or she tries to login the first time. Rules for password complexity can be configured by the HUB system administrator.
- If a user forgets his or her password, then the HUB system administrator can set a new temporary password, again selecting the "Force
basic user to change password on next login" checkbox.
- A user can change his or her password at any time by clicking the Change
Password link in the client login dialog. This is available in all clients. The administrator does not have access to a password set by the user.
- A user will be temporarily locked out if the wrong password given more than N login attempts.
- The HUB system administrator can lock a user account by changing the Status field on the basic user from Active to Locked. The administrator can also unlock a user account by setting status to Active.
When logging into a MOBOTIX HUB system, you may see a warning stating that the system is not secure. Because this release is about securing the communication between system components, the client applications consider any system without a certificate
non-secure. This also includes any previous version, for example if you are using the latest version of MOBOTIX HUB Desk Client with a previous version of the MOBOTIX HUB system
Device firmware update using the Management Client
It is now possible to update device firmware through the Management Client. This new feature allows you to update the firmware for a single device only or for several devices of the same brand/model together. There is a new wizard for bulk firmware
update available in the Maintenance menu of the Management Client.
The new feature makes it easier for the VMS administrators to maintain the latest device firmware when a new firmware is available. This feature is available in the following system versions and for the following device drivers:
- The single firmware update is available for all MOBOTIX HUB products.
- Bulk firmware update is available only for MOBOTIX HUB L4 and MOBOTIX HUB L5.
- Supported drivers are Axis, Bosch, Hanwha and ONVIF.
Note: This feature also depends on the current firmware version of the device. Some old versions do not support a firmware update from MOBOTIX HUB.
Pro Map improvements
Pro Map kann jetzt Kartenelemente verschiedener Typen gruppieren. Dies ermöglicht einen einfacheren Überblick über Systeme mit vielen Geräten an einem Ort. Beim Verkleinern werden Kartenelemente zu Clustern kombiniert, und beim Vergrößern werden die
Cluster auseinander gerissen, bis bei den niedrigsten Zoomstufen Elemente einzeln angezeigt werden. Pro Map kombiniert jetzt einzelne Kameras und andere Geräte zu Clustern, um eine einfache und unkomplizierte Navigation und Visualisierung beim Verkleinern
zu gewährleisten.
Zusätzlich zur bestehenden Unterstützung für die Anzeige von Kamerasymbolen direkt auf der Karte bietet diese Version Unterstützung folgende
Funktionen:
- Input devices:
Display input devices such as door sensors and door bells directly on Pro Map for an even better overview.
- Audio:
Reduce time to action and listen to audio directly from the Pro Map.
- Alarms:
React immediately, when the alarms are marked as blinking red circles on the Pro Map and acknowledge them with a right-click.
Media database repair improvements
Improving the stability of the media database is an ongoing process. In this release, we have improved the repair time for a corrupted media database.
By moving detailed information from low-level index files to higher-level files, we have limited the number of files we need to read to repair the database, thereby significantly reducing the repair time. The time saved depends on the size of the database
and the location where the files are located, but we saved up to 50% time in our tests.
The following is an example of a test performed:
A media database on a local disk with 100,000 corrupted tables showed the following results:
- 2020 R3: 1641 seconds
- 2021 R1: 884 seconds
In this case, we saw a 46% improvement in repair time compared to previous versions
New functions in MOBOTIX HUB add-on products
XProtect LPR
MOBOTIX HUB LPR 2021 R1 contains these new country modules:
- Myanmar
(BUR) - New country module that recognizes all standard license plate
types
- Libya
(LAR) - New country module that recognizes all standard license plate
types
- El
Salvador (ES) - New country module that recognizes all standard
license plate types
Changes and solved issues
General changes
- Prior to MOBOTIX HUB 2021 R1, when changing the hostname of the computer running the Management Server, the Management Server was not able to start again. The Management Server and any other components running on that machine could be fixed manually
or by reinstalling the system. Starting from the 2021 R1 product release, all servers running on a computer that got a new hostname can be re-configured by doing a registration using the Server Configurator.
- Server Configurator is now backwards compatible. Since there is only one Server Configurator installed on a machine, the Server Configurator needs to be able to handle all versions of installed components. We do not support the case in which an older
component is installed on top of newer components. Hence, it is ensured that the Server Configurator is always the same version or newer than the other components on the machine.
Changes in the MOBOTIX
HUB Management Client
- System
monitor now shows the status for failover recording servers. If the
failover server has issues with SSL due to certificate problems or it
cannot authorize with the authorization server, that is shown in
system monitor.
- The generic
de-warping feature has been expanded with an option to specify the
appropriate degrees for the device’s horizontal field of view (FOV).
This enables an improved de-warping experience for a wider range of
devices. The default FOV has been changed to 180 degrees.
- There is a
new tab, Remote Recorder, in the Management Client
for configuring credentials for connections to a remote recorder
device. Such devices can be used as an edge storage for a group of
cameras. Currently this option is only implemented for the Axis Video
Recorder S3008.
- The Menu bar
has been changed. The Edit menu has been removed and
a new menu Maintenance has been added.
- An IP
version filter has been added in Express
scan result screen in the Add
Hardware dialog. This makes it possible to distinguish IPv6 addresses from IPv4 addresses of the same device. By default, only IPv4 addresses are shown.
- A
new time rule is available that can run specifically when in failover,
or not in failover. This makes it possible to lower the resolution and
frame rate when running on a failover recording server. The rule is
not limited to changing these two settings but can be used for general
changes as most other rules.
Changes in the MOBOTIX HUB Web Client
In this application, the functions have been improved:
- Encryption
options have been added to export of investigations results.
- Digital
signing now happens automatically when exporting video.
- Audio
permissions are now requested upon microphone usage.
- One time
export: the Export Investigations link usage has
been limited to one time download. The export link expires after the
first download (in previous versions it did not expire).
- Investigation
retention time added, and investigations are automatically deleted
after this time expires.
Driver improvements for
MOBOTIX IoT cameras
The IoT cameras are now also found on the network and integrated into the system if only the HTTPS protocol, without additional HTTP, is activated on them.
Known Limitations
The
following limitations currently apply to version 2021 R1.
- Insert
MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
- 4K
and 4MP resolutions are not supported.
- It
is better to change exposure and image settings directly on the
camera.
- "Express Search"
This search does not reliably find all cameras (for MOBOTIX drivers
and ONVIF) while searching for address ranges works reliably.
- Setting
up a Failover Server
After setting up a failover server, the status of the failover server
in the Management Client is always displayed incorrectly as a
"connection error". The failover events are also not currently usable
in any way
top
Version 2020 R3 of MOBOTIX HUB
Published on: 2021-05-26
Specific features for MOBOTIX IoT cameras
Note: For additional information about the features described in the following, please see the application's online help.
Dynamic events
After
the integration of MOBOTIX cameras of the series MOBOTIX 7, Mx6 and P3
via a device-specific MOBOTIX driver (selection from Mobotix M/D/V/S series, Mobotix Q*, Mobotix T*), events of these
cameras from the following event groups can also be defined in the HUB
Management
Client for these
cameras as ("dynamic") events:
- Image
Analysis Events
- MxMessageSystem
Events
- Meta
Events
- Environment
Events
The
events defined in the MOBOTIX HUB can then be used in Rules and Alarms, for example to start recording through the HUB Recording Server.
In the MOBOTIX
HUB variants L4 and L5, the HUB
Desk Client Search
dialog allows to search for recordings of such events by entering
MOBOTIX IoT Events as a search filter.
Note: This special search function of the Desk Client requires a MOBOTIX HUB variant L4 or L5..
In order for the events of a MOBOTIX IoT camera to be used as "dynamic
events" in
the MOBOTIX HUB, the following preparations are necessary on the IoT camera before inserting it into MOBOTIX HUB:
- Activation
of the general Arming
- Configuration
of the desired Event
- Activation
of the camera-internal Recording as Event Recording
(e.B. with recording time 2s and recording frame rate 1 fps)
Analytics Events from MOBOTIX 7 Cameras
After
integrating a camera from the MOBOTIX 7 model series via a
device-specific MOBOTIX driver (selection
Mobotix M/D/V/S series), events of a Vaxtor
LPR App activated on the camera for the detection of license
plates, can be defined as Analytics Events
in the MOBOTIX HUB and can also be used within
Rules and
Alarms, e.g. to start a recording.
In
order for the events of the Vaxtor LPR App to be used in the HUB, the
following settings must be made in the
Milestone section of the Vaxtor
LPR
Settings dialog to configure the App:
- URL: <IP
address of the MOBOTIX HUB Management Server>:<Port-Nummer>
- Camera Name:
<IP address of the camera or camera name as defined in the HUB>
After
integrating a camera configured in this way, the corresponding Analytics
Event can then be activated in the HUB Management Client as follows:
- Activation of the
Analytics Events
in the dialog Tools ->
options
The same port number must be used as in the camera configuration in the URL field
(see above).
- Add an Analytics
Event named
VaxALPR
On Camera Event in the Rules and Events
>
Analytics
Events section
in the HUB Management Client's tree structure.
Then,
this Analytics Event can be used just like any other event within Rules
and Alarms.
After installing an extension
of the HUB Desk Client using the installation file
'MOBOTIX_HUB_Plug-Ins_2020_R3_Installer.exe', the Search
dialog of the Desk
Client
then displays an additional search area
VaxALPR,
which allows the search for a specific licence plate recognized by the app. By displaying this search area multiple times, it is also possible to search for several licence plates at the same time.
Note: This special search function of the Desk Client requires a MOBOTIX HUB variant L4 or L5..
Known Limitations
The
following limitations currently apply to version 2020 R3.
- Insert
MOBOTIX IoT Cameras via device-specific MOBOTIX drivers
- On
the cameras, the HTTP protocol must be active and used for
integration.
- 4K
and 4MP resolutions are not supported.
- It
is better to change exposure and image settings directly on the
camera.
- "Express Search"
This search does not reliably find all cameras (for MOBOTIX drivers
and ONVIF) while searching for address ranges works reliably.
- Setting
up a Failover Server
After setting up a failover server, the status of the failover server
in the Management Client is always displayed incorrectly as a
"connection error". The failover events are also not currently usable
in any way.
Copyright ©
2021, MOBOTIX AG, Germany, support@mobotix.com